Home >

AP type motor-driven grease pump






















​AP type motor-driven grease pump are specially designed for automotive chassis (like bus, truck), trailer, engineering machinery, etc. It is suitable for NLGI 000#-0# lubricant. The system generally runs at low pressure, typically the output pressure is rated to 3.8Mpa.
 
AP type motor-driven grease pumps are applicable for AD volume-type distributor, RH-3 volume-type distributor,35 series pressure volume-type distributor to combine with low pressure grease lubrication system. When not installing pressure take-off device to AP type motor-driven grease pump, it is applicable for U-type progressive distributor, SD type progressive distributor to combine with low pressure grease lubrication system.
 
 
1. Technical Parameters
 
 
Model: AP-32-300X /AP-31-300X
Style: AP type motor-driven grease pump
Reservoir Capacities: 3 L (3 kg)
Reservoir Material: PC
Suitable Grease: NLGI000#-0#
Operating Voltage: DC12V/DC24V
Discharge Capacity: 260 m L/min
Working Pressure: 3.5-3.8 MPa
Protaction Rate:  IP55
 
\
 
 
2.  Installation Size
 
 
     \
 
3.  Model number and rules to guide how to order 
 
\
             
                                     X: Built-in pressure take-off mechanism, 
for use with fixed volumetric type distributor
                                     T: Without pressure take-off mechanism,
                                        for use with resist-type distributor
 
                                       Pressure Switch action pressure:
                                        20= 20 kgf/cm2  00= without pressure switch
 
                                       Reservoir Capacity: 3=3L
 
                                       Motor Type: 1= DC12V  2= DC24V
 
                                       Discharge Capacity Per Minute :
2=100~200cc/min  3=200~300cc/min  4=300~400cc/min
 
                                        Code of Motor-driven Grease Pump
 
Example: AP-32-300X indicates that it is a grease pump with discharge capacity of 200-300 cc/min, with DC24V, with reservoir of 3L, with built-in pressure take-off mechanism and level switch.
 
4. Specifications
 
Model Discharge capacity Operating pressure Reservoir capacity (L) Voltage (V) Viscosity  Outlet pipe size
AP-32-300X 260mL/min
 
 
3.5-3.8Mpa
 
3.0
DC24V  
NLGI000#-0#
 
M16X1.5 (∮10 pipe)
AP-31-300X 260mL/min
 
DC12V
 
NK-5 type Vehicle-mounted Program Controller 
 
 
A. Overall and Installation Dimensions
\ 
 

B. Mounting-hole Size
C.  Mounting space of AP pump
\     \\
 
Operation Instruction
 
1. After connecting power, power indicator (yellow) lights on, malfunction indicator (red) lights for 2 seconds and then goes off. The system automatically enter intermittent time counting (if last power off is malfunction state, the system will first enter motor pumping oil time counting).
 
2. Open the panel of the display, and you will see a row of LD indicators and buttons. LD1-LD6 are motor rotary intermittent time indicator, standing for 0.5, 1, 2, 4, 8 and 16 hours respectively. For example, LD1 indicator lighting means the motor turns once every 0.5 hour,  LD2 indicator lighting means the motor turns once every 1 hour, LD3 indicator lighting means the motor turns  once every 2 hours. LD1 and LD2 indicators lighting simultaneously means the motor turns once every 1.5 hours,  LD1, LD2 and LD3 indicators lighting simultaneously means the motor turns  once every 3.5 hours. The intermittent time of motor turning is between 0.5 and 31.5 hours, altogether 63 options, corresponding the combinations of LD1 to LD6. Use KEY 2 (▲) and KEY3 (▼) to adjust intermittent time, each press of KEY 2(▲) or KEY 3(▼) increases or decreases intermittent time by 0.5 hour, with the corresponding indicators lighting and others off. Set motor turning time has power-off memory function. Since lubrication pump working time and intermittent time have been factory set professionally, it is recommended that no changes be made. The default setting is the optimal. If you really need to adjust the time, please do it when guided by a professional, to prevent system damage.
 
3. Whenever timer counting to the set intermittent time for motor turning, the motor starts turning, at the same time working indicator (green) lights up (working indicator only lights when motor turns). During the set motor turning, the programming system keeps checking the pressure signal of the lubrication system, so long as the pressure sensor closes once (or more than once), it means pressure is adequate. If pressure is checked to be adequate , normal indicator lights up (green), the motor continues to turn for a system feedback period (a few seconds) and then stops, and normal indicator and working indictor both go off. And then the system enters the next intermittent time counting. When intermittent time counting to 15 minutes, the programming system tests pressure take-off inside the system. The lubrication system should be in pressure take-off state, and if the programming system checks that the lubrication system is not in pressure take-off state, the motor will stop, the working indicator will go off, and malfunction indicator (red) will light up, the alarm sounds 8 times.
 
4. When malfunction occurs, press KEY 0 Reset     to clear malfunction output, and the malfunction indicator will go off and the system will reset, and start counting according to the set motor turning intermittent time.
 
5. Press KEY 1 ( Manual ) and intermittent time indicators will all go off, and motor will start turning. After motor starting turning, the processes will be as stated in Item 2.
 
6. Programmer controlled system has memory function, the counting value will be kept after power cut off, and counting will continue on lst value when power is on. If motor turning intermittent time is set to be 8 hours, and if the timer has counted 6 hours by last power-off, another 2 hours shall be counted after power is on and the motor will start turning.
 
7. First press and hold on KEY 0 and then press and hold on KEY1 for 3 seconds, a “ du” sound will be heard to indicate locking of keys. Operate in such sequence once again to unlock the keys.
 
Warning: Please read the Automotive Programmer Controlled System Operation and Wiring Instructions carefully, and protect programming panel against pressing of heavy matters or unauthorized persons, so as to avoid malfunctions of control system or lock of keyboard.
 
D. Connection instruction of NK-5 type vehicle-mounted Program Controller
 \

AD Type Volumetric Distributor
 
AD Volume type distributor is designed and manufactured by Nihon Yuki Co., Ltd based on patented product RH volume type distributor to special installation and piping needs. In design and material selection, full consideration has been made. Advanced Japanese processing techniques and testing measures are adopted to guarantee reliably, and service life of the distributor.
 
 
1. Working Principle
 
As shown in diagrams below, grease press delivered from lubrication system is injected via main pipe (A), and injected by push opening the umbrella-shaped valve (B),and press delivered via channel (C) into piston chamber (F). Pressured oil causes measurement piston to go upward, and the spring (G) is compressed, and measured oil reserve takes place.
 
When grease pressure in main pipe (A) is taken off, the umbrella-shaped valve (B) moves leftwards due to pressure difference, and at the same time opens the outlet (E). Then grease inside the piston chamber enters oil pipe (H) via outlet (E) due to spring force. Thus, one grease delivery cycle is finished.
 
\   \     \    (1) Intermittent state      (2) Main tube pressurizing and measuring       (3) Oil discharge
                 
     a. Travel of metering piston
  b. Travel of umbrella-shaped valve 
 
 
 
 
 
 
2. Configuration and Installation Size 
     \
Installation Size
\ 
3. Specifications
 
Model
 
Number of oil outlets
 
Working pressure (MPa) Commonly used discharge volume (C.C.) Grease used (NLGI) Installation hole
 
Center spacing
 
Overall dimension (L x H x T) (mm)
AD2 2 2.5-5.5 0.1
0.2
0.4
0#
00#
000#
2 – 6.5 50 62 X76X55
AD3 3 79X75X55
AD4 4 96X76X55
AD6 6 130X76X55
 
4. AD type distributor model number and rules
 
\
                               Discharge capacity of the 6th outlet
                                    Blank: Distributor with 2,3,5 outlets or all outlets have the same capacity
 
Discharge capacity of the 5th outlet
                                   Blank: Distributor with 2 or 3 outlets or all outlets have the same capacity
                                  
Discharge capacity of the 4th outlet
                                  Blank: Distributor with 2 or 3 outlets or all outlets have the same capacity
 
                                  Discharge capacity of the 3th outlet
                                  Blank: Distributor with 2 outlets or all outlets have the same capacity
 
                                  Discharge capacity of 2nd outlet
                                  Blank: have the same capacity as the 1st outlet
 
                                  Discharge Capacity of the 1st outlet
                           
                                 Number of outlets
Capacity expressions:
 
10 means 0.1ml/time, 20 means 0.2ml/time, 30 means 0.3ml/time, 40 means 0.4ml/time
Example 1: AD6103010203030 indicates that it is an AD type distributor with six outlets whose discharge capacity 
          is 0.1, 0.3, 0.1, 0.2, 0.3, 0.3 ml/time respectively.
Example 2: AD230 indicates that it is an AD type distributor with 2 outlets, both of which have the discharge  
          capacity of 0.3ml/time.
  • Would you like to know more information? please leave your message